Product
Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature - 82000-2
The Setaflash Series 8 closed cup flash point tester provides fast and reliable flash point results with a wide temperature range from ambient to 300 °C with no external cooling required.
With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores test results which can be saved and transferred via a USB port to a laboratory information management system (LIMS).
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Learn more about flash point testing and which instrument you should be using >
Why flash point autosamplers do not comply with flash point test methods >
Features
- Simple test procedure
- Compact, rugged design
- Electric ignition
- Automated flash detection
- Ramp mode for unknown samples
- Statistical quality control system
- Automatic barometric pressure correction
- Fire detection (alarm and relay)
- USB port and result storage
Information
Details
Ease of use:All functions on the Series 8 including test parameters, instrument status and test results are accessed via the touchscreen display. An audible prompt sounds when a flash is achieved and an automatic flash detector enhances repeatability.
Safety:
A fire sensor immediately stops the test and cools the sample cup if a fire is detected.
Statistical quality control:
The statistical quality control (SQC) analysis feature allows you to analyse the results of previous tests, calculating mean, standard deviation, standard error and repeatability, and plotting results in accordance with ASTM D6299. You can analyse all the results stored or selected results.
Calibration and verification:
Calibration of the Series 8 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service centre.
Service and maintenance:
The rugged design ensures minimal operational maintenance is needed.
Supplied with: 2 ml syringe, 99878-3 CRM, Allen keys, mains lead and instruction manual.
Application resources
Sustainable Aviation Fuel (SAF) Testing > Explore the role of flash point testing in Sustainable Aviation Fuel quality control and learn how ASTM compliant testing supports fuel safety, certification and regulatory compliance
Details
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
|---|---|
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature | |
| Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature |
Details
| Temperature range | Ambient to 300 °C |
|---|---|
| Temperature selection | °C or °F |
| Ignitor | Electric |
| Heating/cooling method | Ceramic hotplate and fan |
| Temperature ramp mode | Automatic or custom settings (ramp rate up to 10 °C/min) |
| Sample cup material | Aluminium |
| Pressure correction | Automatic |
| Data storage | 12 GB |
| Voltage | 110 to 240 Vac, 50/60 Hz auto-sensing power supply |
| Size (HxWxD) | 30 cm x 34 cm x 38 cm |
| Weight | 8 kg |
| CCCN Code | Tariff 90268020 |
Methods
Industries
Spares and accessories for Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature - 82000-2

Printer Paper (Pack of 20) - 80602-001
View accessory
Flash Detector for Series 8 - 82000-201
View accessory
High Temperature Ignitor for Series 8 and Series 3 - 82000-202
View accessory
Syringe 4 ml (Small Scale Flash Point Instruments) - 13770-311
View accessory
Seta Solid Sample Dispenser - 13747-0
View accessory
Seta Metal Cooling Block - 13880-0
View accessory
Sample Well O-Ring Ekraz - 82000-018
View accessory
Syringe 2 ml (Small Scale Flash Point Instruments) - 13740-009
View accessoryDownload product profile
To view our full range of products, download our latest Product Profile here.

Want to know more?
View our full range of products, or simply get in contact with us for more information.