Product
Setaflash CCC Continuously Closed Cup Flash Point Tester - 35600-0
The Setaflash CCC Continuously Closed Cup Flash Point Tester is an automatic flash point analyser designed for fast, accurate and repeatable determination of flash point using minimal sample volumes. Engineered for safety, efficiency and compliance, it is ideally suited to laboratories testing fuels, lubricants, biodiesel, sustainable aviation fuels (SAF), solvents and chemicals.
The Setaflash CCC combines low sample volume closed cup flash point testing with advanced automation, making it a reliable alternative to traditional large-sample flash point methods.
Automatic Continuously Closed Cup Flash Point Testing
The Setaflash CCC performs continuously closed cup (CCC) flash point testing in full compliance with:
- ASTM D6450
- ASTM D7094
- IP 620
Using sample volumes as low as 1–2 mL, the instrument reduces waste, operator exposure and testing costs while maintaining excellent repeatability and accuracy.
Features
- Wide temperature range in a single model
- Removable cup, easy to clean
- Unique automatic magnetic stirrer detection
- Built-in Peltier cooling
- Optional external chiller connection
- Built-in fire extinguisher
- Emergency stop button
- Statistical Quality Control software
Information
Details
Designed for operator safety:Safety is fundamental to closed cup flash point testing. The Setaflash CCC includes multiple layers of protection:
- Optical fire detection with automatic inert gas deployment
- Built-in fire extinguisher, with manual activation available at any time
- Pre-test safety arcs warn of ignition risks with highly volatile samples
- Over-temperature cut-out protects the instrument from unsafe conditions
- Independent emergency stop button can be positioned at a safe distance from the instrument
Precision, accuracy and compliance:
As an automatic flash point tester, the Setaflash CCC minimises operator influence and ensures consistent results through:
- Fully automated flash point determination
- Automatic barometric correction using an internal pressure sensor
- Password-protected calibration mode for performance verification
- Magnetic stirrer detection to confirm correct test conditions
- Statistical Quality Control (SQC) for monitoring repeatability, mean, standard deviation and compliance with ASTM D6299
High throughput flash point testing
To maximise laboratory productivity, the Setaflash CCC includes:
- Quick Test function that pre-heats the instrument before sample introduction
- Rapid Peltier-assisted cooling after each test
- Customisable test profiles, eliminating repeated data entry
- Easy-to-clean removable cup, reducing turnaround time between samples
Intuitive touchscreen operation
All routine functions are accessed through a large industrial colour touchscreen allowing operators to:
- Enter test parameters quickly
- Monitor real-time test progress
- View graphical results and trends
- Export data to LIMS, USB, network or QR code
Why choose the Setaflash CCC?
- Trusted Stanhope-Seta flash point expertise
- Fully compliant continuously closed cup methodology
- Minimal sample volume reduces risk and waste
- Advanced safety features as standard
- Designed for modern, accredited laboratories
Details
| ASTM D6450 | Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester |
|---|---|
| ASTM D7094 | Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Teste |
| IP 620 | Standard test method for flash point by modified continuously closed cup (MCCCFP) tester |
Details
| Temperature range | -5 °C to 420 °C -15 °C to 420 °C with external chiller |
|---|---|
| Ignition system | Electric arc |
| Flash detection | Pressure increase = 20 kPa |
| Ramp rate | 5.5 °C (ASTM D6450) 2.5 °C (ASTM D7094) |
| Fire detection | Optical |
| Sample size | 1 mL (ASTM D6450 (test cup available as an accessory)) 2 mL (ASTM D7094 (test cup included)) |
| Cooling method | Peltier (liquid cooled with chiller) |
| Stirrer | Magnetic with detection |
| Units of temperature | °C or °F (user selectable) |
| Barometric pressure correction | Automatic correction with built-in pressure sensor |
| Voltage | 110/240 VAC, 50/60 Hz, Auto-sensing universal power supply |
| Power | 200 W |
| Size (HxWxD) | 43 x 24.9 x 32 cm |
| Weight | 16.3 kg |
Methods
Spares and accessories for Setaflash CCC Continuously Closed Cup Flash Point Tester - 35600-0
Download product profile
To view our full range of products, download our latest Product Profile here.

Want to know more?